Product Numbers and Accessories
AMPLATZER® Septal Occluder
| Order Number |
Device Size
(Diameter of ASD) |
Minimum Recommended Sheath Size (AMPLATZER® TorqVue® Delivery System) |
Minimum Recommended Sheath Size (AMPLATZER® Delivery System) |
| 9-ASD-004 |
4 mm |
6 French, 45º Curve |
6-7 French, 45º Curve |
| 9-ASD-005 |
5 mm |
6 French, 45º Curve |
6-7 French, 45º Curve |
| 9-ASD-006 |
6 mm |
6 French, 45º Curve |
6-7 French, 45º Curve |
| 9-ASD-007 |
7 mm |
6 French, 45º Curve |
6-7 French, 45º Curve |
| 9-ASD-008 |
8 mm |
6 French, 45º Curve |
6-7 French, 45º Curve |
| 9-ASD-009 |
9 mm |
6 French, 45º Curve |
6-7 French, 45º Curve |
| 9-ASD-010 |
10 mm |
6 French, 45º Curve |
6-7 French, 45º Curve |
| 9-ASD-011 |
11 mm |
7 French, 45º Curve |
7 French, 45º Curve |
| 9-ASD-012 |
12 mm |
7 French, 45º Curve |
7 French, 45º Curve |
| 9-ASD-013 |
13 mm |
7 French, 45º Curve |
7 French, 45º Curve |
| 9-ASD-014 |
14 mm |
7 French, 45º Curve |
7 French, 45º Curve |
| 9-ASD-015 |
15 mm |
7 French, 45º Curve |
7 French, 45º Curve |
| 9-ASD-016 |
16 mm |
7 French, 45º Curve |
7 French, 45º Curve |
| 9-ASD-017 |
17 mm |
7 French, 45º Curve |
7 French, 45º Curve |
| 9-ASD-018 |
18 mm |
8 French, 45º Curve |
8-9 French, 45º Curve |
| 9-ASD-019 |
19 mm |
8 French, 45º Curve |
8-9 French, 45º Curve |
| 9-ASD-020 |
20 mm |
9 French, 45º Curve |
8-9 French, 45º Curve |
| 9-ASD-022 |
22 mm |
9 French, 45º Curve |
9 French, 45º Curve |
| 9-ASD-024 |
24 mm |
9 French, 45º Curve |
9 French, 45º Curve |
| 9-ASD-026 |
26 mm |
10 French, 45º Curve |
10 French, 45º Curve |
| 9-ASD-028 |
28 mm |
10 French, 45º Curve |
10 French, 45º Curve |
| 9-ASD-030 |
30 mm |
10 French, 45º Curve |
10 French, 45º Curve |
| 9-ASD-032 |
32 mm |
12 French, 45º Curve |
12 French, 45º Curve |
| 9-ASD-034 |
34 mm |
12 French, 45º Curve |
12 French, 45º Curve |
| 9-ASD-036 |
36 mm |
12 French, 45º Curve |
12 French, 45º Curve |
| 9-ASD-038 |
38 mm |
12 French, 45º Curve |
12 French, 45º Curve |
| IMPORTANT: Device Selection is based on the balloon measured diameter of the defect (i.e., a 10 mm defect will require a 10 mm device). |
AMPLATZER® Multi-Fenestrated Septal Occluder – "Cribriform"
| Order Number |
Device Size
(Diameter of ASD) |
Minimum Recommended Sheath Size (AMPLATZER® TorqVue® Delivery System) |
Minimum Recommended Sheath Size (AMPLATZER® Delivery System) |
| 9-ASD-MF-018 |
18 mm |
8 French, 45º Curve |
8 French, 45º Curve |
| 9-ASD-MF-025 |
25 mm |
8 French, 45º Curve |
8-9 French, 45º Curve |
| 9-ASD-MF-030 |
30 mm |
8 French, 45º Curve |
9 French, 45º Curve |
| 9-ASD-MF-035 |
35 mm |
9 French, 45º Curve |
9 French, 45º Curve |
|
|